Preview build. Not indexed.

Overflow filler wastes

Published

A bath filler overflow waste fills the tub through the overflow fitting. How it works, backflow protection, pressure and flow checks, access and fitting points.

An overflow filler combines two jobs in one fitting: bath water enters through the overflow face and surplus water leaves through it, with the plug waste below. It removes the spout from the rim, but it adds hidden supply pipework and a backflow question that must be settled before purchase.

The parts

  • A combined overflow face with a water inlet.
  • A waste with clicker or pop-up operation.
  • A trap.
  • A separate mixer or valve to control temperature and flow, often rim or wall mounted.
  • A supply pipe or hose from that control to the filler.

McAlpine's bath trap range includes chrome plated brass bath filler and overflow sets in clicker, pop-up and top access forms, as one example of how the options differ.

Backflow protection

Because the inlet sits at overflow level, bath water can reach it. If supply pressure dropped, dirty water could be drawn back towards the pipes. The water fittings regulations require every water system to have adequate protection against backflow. The right device depends on the fluid risk and the product's approval. Check the filler's installation requirements, look for water regulations approval information, and fit the check valves or other arrangement it specifies. Where the paperwork is vague, ask the water company or choose a different product.

Pressure and flow

Water must pass through a mixer, a hose and a narrow slot. On a gravity fed hot supply the fill can be very slow. Compare the minimum operating pressure on both the filler and its control with what your system provides, and look for a published flow rate.

Access

Joints and operable parts should not be buried. The control valve, any check valves and the trap all need to be reachable. Plan a removable bath panel and, for a wall mounted control, a service hatch. See fitting a bath panel.

Fitting outline

  1. Confirm the overflow and waste hole sizes and the distance between them.
  2. Check space between the bath wall and the room wall for the supply connection.
  3. Fit the overflow filler with seals in the order given.
  4. Route the supply from the control without kinks, supporting it so it cannot chafe.
  5. Fit backflow devices in the correct direction, following the arrows.
  6. Fit waste and trap; Approved Document H lists a 40 mm trap and 50 mm seal for baths.
  7. Flush the pipes before connecting the fitting so grit cannot lodge in valves.
  8. Test pressurised joints first, then fill, then the overflow, then drain.

Before the panel goes on

Run several complete fills at normal hot water temperature, since joints that stay dry cold can weep after heating and cooling. Press the supply hose gently to confirm it is not rubbing on the bath edge, a joist or a panel batten. Write down the model number and leave the instructions where the next person can find them, because the cartridge, check valves and overflow face are specific parts. Photograph the finished pipework before closing the access.

Faults to expect

Symptom Possible cause
Slow fill Low pressure, debris, kinked hose
Drip behind panel after filling Supply joint or overflow seal
Water continues briefly after shut off Hose draining down
Tepid water Mixer setting or unbalanced supplies

A leak on the supply side of a filler is under pressure whenever the control is open, so treat any damp under the bath seriously.

Is it worth it

It suits a small bathroom or a bath with nowhere neat for a tap. It is a poorer fit where the underside is inaccessible or pressure is low. To discuss a particular product, put its link and your hot water system type in the contact form, then email a photo under the bath.

One list, however many jobs

Add what needs fitting or replacing, tell us the postcode, then email photos.

Send my job list