How to fit a bath panel: test the fit, trim it accurately, set a floor batten, deal with uneven floors and pipes, and keep access to the bath waste.
A bath panel tucks or clips under the rim at the top and is fixed to a batten or the floor at the bottom. The job is mostly measuring: get the height and the batten line right, and the panel goes in without bowing.
Check the old panel first
In a home built or refurbished before 2000, boards and panels may contain asbestos. HSE's asbestos diagrams include bath panels among places it can be found. A hard, cement-like or fibrous flat board should be left intact until identified. Do not saw, sand, snap or drill it.
What you need
- The new front panel, plus an end panel if one side is exposed.
- A fixing batten if the panel needs one, often planed softwood or the strip supplied.
- Tape measure, level, fine-toothed saw, drill and screws.
- A pipe and cable detector.
- Cover caps or the maker's clips.
Measure and dry fit
- Measure floor to underside of rim at both ends and the middle.
- Measure the length, including any overlap at a corner with the end panel.
- Hold the panel in place without fixing it. Note skirting, pipes or flooring that obstruct it.
- Check which edge is top. Decorative panels are not always reversible.
A panel that is too tall by a few millimetres will bow. One that is short may be rescued by a plinth if the maker sells one.
Trim it
Mark the cut on the bottom edge or the hidden end, leaving the finished top untouched. Support the whole length so it cannot crack, and cut slowly with the teeth entering the visible face. Remove a little less than you think, test, then dress the edge with fine abrasive. A B&Q panel guide recommends buying the correct size where possible and cutting with a hacksaw.
Set the batten
- Stand the panel plumb under the rim and mark its position on the floor.
- Take away the panel. Draw a second line behind it, allowing for the panel thickness or the lip that sits behind.
- Scan for pipes and cables before drilling the floor. Underfloor heating pipes make floor screws unsafe unless their positions are certain.
- Fix the batten to the line. A panel with a bottom lip needs a rebated batten that the lip can slide under.
- Add short uprights at the ends if the design calls for them, keeping clear of the waste and taps.
Fit the panel
Slide the top behind the rim, ease the bottom into position and check level. Drill clearance holes in the panel before screwing, so it does not split. Use dome caps or clips so it can be removed without damage. Fit an end panel in the sequence that hides its edge from the usual view.
Uneven floors
Where the floor falls away, scribe the bottom edge: hold the panel level, run a pencil on a packer along the floor, then trim to the line. Do this only on a material that can be cut cleanly.
Keep access
The waste trap, overflow hose and tap connections live behind that panel. Approved Document H says traps should be removable or have a cleaning eye, and a panel that unscrews is what makes that useful. If you tile onto a panel, build in a proper access hatch.
Before closing up, fill the bath, release it and run a dry sheet of paper under every joint.
Finishing edges
Water that runs down the wall should meet a seal at the rim, described in how to reseal a bath. Leave the floor edge unsealed or lightly sealed according to the maker, so a hidden leak has a chance to show.
If you find damp timber, a weeping joint or corroded pipes behind the old panel, stop and describe it through the contact form before covering it again.
Questions people ask
Should a bath panel be sealed all round?
Keep it removable. A light seal where water lands is reasonable, but glueing it permanently blocks access to the trap and tap connections.
Can I cut an old panel to reuse it?
Do not cut or drill a panel of unknown age until you know what it is made of, because some older boards contain asbestos.