Tank-fed copper and factory-foamed cylinders: how the vent and feed work, common faults, what to measure for a replacement and when to consider a change.
A vented cylinder is filled from a cold water cistern placed above it, and a vent pipe runs from the top of the cylinder to discharge over that cistern. Cylinder specialists are available for faults, valve changes and like-for-like replacement.
How the parts work together
The cistern sets the pressure at your hot taps, which is why upstairs outlets close to its level can be weak. The vent leaves heated water room to expand and an open path if it overheats. Guidance in Approved Document G calls for a vent of at least 19mm internal diameter and, in addition, an overheat protection device suited to the heat source. Nobody should valve off or cap the vent.
Common faults
| Symptom | What may be behind it |
|---|---|
| Lukewarm water | Immersion, thermostat, boiler coil or control valve |
| Water runs out too soon | Small cylinder, lost insulation or scale |
| Weak hot flow | Low cistern, narrow pipe, part-closed valve |
| Overflow dripping outside | Filling valve on the cistern |
| Green or white crust at a joint | A slow weep that has dried |
| Water under the cylinder | A fitting, or the cylinder itself failing |
Safe first steps
Turn off the immersion at its isolator and the heating or hot water control. If water is escaping, close the valve on the cold feed to the cylinder if you know which it is, then open a hot tap to relieve what is stored in the pipes. Keep away from scalding water. Do not drain the cylinder with power still on to the immersion.
Replacing a cylinder
Measure the height and diameter, including insulation, and photograph every connection with the one above or below it so their heights are clear. A newer cylinder can be a different shape even at the same capacity. Check also:
- whether it is direct, heated by immersion only, or indirect with a boiler coil
- the number of immersion bosses needed
- the condition of the cistern, its lid, insulation and support
- whether the access hatch and doorway will take the old and new units
Where the boiler or its gas supply is altered as part of the change, that part is done by a Gas Safe registered engineer.
Staying vented or changing type
Changing to a mains pressure cylinder removes the loft cistern and can improve showers, but only if the incoming main can supply it, and it brings G3 requirements and a building control notification. Ask for flow and pressure readings before comparing quotes. A shower pump is another route for weak showers on a tank-fed system.
What to send
The postcode, photos of the cylinder and loft cistern emailed with your reference, the symptom, the heat source and any stamped label giving capacity or grade. Say whether you have had a similar repair before.
After the work
The system is refilled slowly, air is run out at the hot taps and every joint is checked cold and then hot. Ask for the thermostat setting to be confirmed and for the old cylinder's removal to be included in writing.
Questions people ask
Why is water coming out of the pipe over the loft tank?
It can mean the water is overheating or the system pressures are wrong. Switch off the heat to the cylinder and have it examined before using it again.