Who can fit an electric shower? The wiring needs a competent electrician and often notification; the water connection is plumbing. How to split the job safely.
An electric shower is two jobs. The electrical supply should be installed and certified by a competent, ideally registered, electrician. The cold water connection is plumbing. One person may be qualified for both; if not, book both and agree who commissions the unit.
What the safety guidance says
Electrical Safety First states that an electric shower must be installed by a registered competent electrician and be supplied on its own circuit, and that circuits in bathrooms and shower rooms need RCD protection.
Manufacturers set their own conditions. A Triton T90SR installation booklet requires installation by a suitably qualified person and a double pole isolating switch in the fixed wiring. That model is also for a gravity fed supply from a cold water storage cistern only, and the booklet says it must never be connected directly to the mains. Other models need mains cold water, so check which type yours is before any pipe is connected.
Building regulations
In England, regulation 12 requires notification for a new circuit, a replacement consumer unit, or any addition or alteration to circuits in a special location such as the space around a bath or shower. A registered electrician can normally self certify; otherwise building control is involved before the work.
Replacing a shower like for like on an existing circuit is not one of the cases regulation 12 lists, unless the circuit in the special location is added to or altered. It still has to be safe: a new unit with a higher kilowatt rating may exceed what the existing cable and protective device can carry. Approved Document P is the government guidance on electrical work in homes.
Divide the work
| Task | Who |
|---|---|
| Check consumer unit, cable and protective devices | Electrician |
| New circuit, isolator, final connection, testing | Electrician |
| Isolation valve and cold feed | Plumber |
| Mounting unit, flushing pipe, leak test | Either, as the instructions allow |
| Certificates | Electrician |
| Tiles and sealing | Bathroom trade |
Water side points
- Check the booklet for the supply type and pressure range, because a mains fed model and a tank fed model are not interchangeable.
- Flush the pipe before connecting so grit does not damage the unit.
- Fit an isolating valve you can reach.
- Do not solder close to the shower unit where the instructions forbid it.
- Run water through the unit before it is powered, as the commissioning steps require.
Replacing like for like
Record the old model, kilowatt rating, pipe entry side and cable entry. Many new units offer multiple entry points, but check against the actual wall. Isolate the circuit and confirm it is dead before any cover comes off. Proving that is the electrician's skill.
Warning signs
Stop using the shower and call an electrician if you smell burning, see scorching or melted plastic, notice water inside the casing, or the protective device trips.
Tenants, landlords and flats
A tenant should report a faulty electric shower to the landlord or agent and not arrange wiring changes without permission. A landlord should keep the electrician's certificate with the property records. In a flat, check whether the consumer unit has spare capacity and whether the lease requires consent for new circuits or pipe runs through shared parts. Ask for the quotation to say who supplies the unit, who connects each side and which certificate you will receive.
Considering a mixer instead
Swapping to a mixer shower changes both jobs: it needs hot and cold supplies at the shower position, and the old circuit must be safely disconnected by an electrician.
If you want the water side arranged, ask in the contact form and email the unit's label, a photo of the pipe and the consumer unit make. Electrical work is a separate competence and should be agreed with an electrician.