Shower bar valve centres: most bar mixers use 150 mm spacing with 15 mm inlets. Set level pipes, correct projection, solid brackets, flush and then test.
Most exposed bar shower mixers are made for inlets 150 mm apart, centre to centre, with 15 mm connections. Confirm that on your model's sheet, then set the pipes level, square and at the correct projection through the finished wall.
Manufacturer figures
A Bristan Buzz guide specifies 15 mm compression inlets at 150 mm centres, a working range of 0.5 to 5 bar and balanced supplies, with a pressure reducing valve where unequal. Another Bristan sheet also shows supply pipes 150 mm apart. These are good examples, not a universal rule.
Setting out
| Item | Check |
|---|---|
| Centres | Measure between pipe middles |
| Level | Both outlets at the same height |
| Projection | Pipe length beyond the tile face as stated |
| Square | Pipes at right angles to the wall |
| Height | Comfortable and clear of spray |
| Hot side | As marked on the valve |
A fixing bracket or backplate kit holds the pipes at the right distance while the wall is built and carries the valve afterwards. Mount it on solid backing or a stud noggin. Relying on the pipes alone lets the shower move and breaks joints.
Concealed pipework
The pipes behind the wall must not contain joints in places nobody can reach, since the water fittings rules restrict concealed joints. Run continuous pipe to an accessible point, secure it and cap the ends.
Temperature and pressure
Check that hot water is hot enough above the blend setting; the Buzz guide asks for at least 10 degrees above the outlet temperature. Gravity systems may not suit a bar valve needing 0.5 bar; see pump types or choose a valve rated lower.
First fix
- Choose valve and obtain the drawing.
- Mark finished wall and tile thickness.
- Fix the bracket level.
- Run supplies and flush them thoroughly. Debris damages cartridges.
- Cap and pressure test.
- Waterproof around the pipes with collars.
- Photograph before closing.
Second fix
Seal tile holes, fit the shrouds, check the filter washers or inlet strainers are in place, then tighten the unions on the valve using a cloth to protect chrome. Do not overtighten. Turn on supplies slowly and check both joints. Set the thermostatic control as the maker describes and verify with a thermometer.
Replacing an old mixer
If existing pipes are not 150 mm apart or not level, eccentric adapters may absorb a small error if the maker allows them. Larger errors mean opening the wall. Measure the old valve and pipe positions before buying.
Isolation and flushing
The Bristan 547149 sheet calls for isolation valves on both inlets and thorough flushing to remove swarf and solder before the shower is fitted. Check where those valves will sit once the wall is tiled.
Problems
| Symptom | Check |
|---|---|
| Valve tilts | Pipes not level |
| Gap behind shroud | Wrong projection |
| Only hot or cold | Crossed supplies or closed valve |
| Poor flow | Debris in inlet filters |
Describe the existing pipes and chosen valve through the contact form and email measured photos with your reference.
Choosing the fixing kit
Backplates, wall mount kits and eccentric unions are usually specific to a valve family. Order the kit with the shower, check whether it suits stud or solid walls and keep its instructions for the tiler. A kit fitted before tiling holds the centres reliably; one added afterwards depends on pipes that may already be out of true. Note where the kit's screws fall so that they cannot strike the supplies.
Checking after use
Run the shower for ten minutes once the sealant has cured, then look at the room behind the wall and the ceiling below. Feel around the shrouds for weeping at the unions during the first week.
Questions people ask
Are all bar mixers 150 mm apart?
Many are, but read your instructions. A few designs differ or allow adjustment.
Which side is hot?
Commonly left as you face the wall. Check the markings on your valve.