Fit or replace a shower tray

A level shower tray on adjustable legs with its trap and waste pipe underneath

Fit a shower tray with the right base and waste: what to measure, how bedding, trap access and sealing work, and when a replacement becomes a bigger job.

Fitting a shower tray involves preparing a firm, level support, connecting a trap and waste pipe, bedding the tray, then finishing the wall joints. A like-sized replacement can still involve tiles, flooring and moved pipework.

Parts of the job to agree

  • disconnecting and removing an old tray;
  • checking the floor and walls once exposed;
  • fitting the compatible waste and trap;
  • bedding and levelling the new tray;
  • connecting and testing the waste;
  • sealing the agreed edges.

Tiling, waterproof wall panels, floor repair, screen refitting, electrical work and disposal should each be listed as included or excluded. No price is published; ask for the basis before booking.

Measure before ordering

Record finished wall-to-wall dimensions, the open sides, door swing, waste centre and floor construction. Check whether the tray is handed left or right. Walls are seldom perfectly square, so measure more than one point. The measuring sheet sets out each item.

Waste and fall

Approved Document H gives a minimum 40 mm trap and 50 mm seal for a shower. Low-profile trays leave little depth, so a solid floor may require a raised installation or a recessed pipe route. The tray, waste body and trap must be compatible, and there should be a practical way to clear the trap, commonly through the top or an access panel.

The pipe needs to run to the drain with an appropriate fall. Moving the tray further from the stack can change what is possible; raise this before selecting a design.

Bedding and support

Use the method printed with the tray. For one acrylic-capped tray, the Simpsons instructions require a firm, level, clean location, then a weak 5:1 sand and cement bed or tile adhesive. They have the fitter bed the tray with gentle hand pressure, level it, let it set, connect and check the waste, then seal joints with anti-fungal silicone. Resin and stone trays, trays on legs and wet-room formers may use different methods.

Do not leave voids that the manufacturer says should be supported. Timber floors need inspection for movement and rot.

Replacing an old tray

The hidden condition becomes clear only after removal. Tiles may overlap the lip, so removing the tray can damage the lower row. Take a photo of any cracked grout, staining or soft floor and mention it. Leak investigation and repairs to concealed damage need to be agreed separately, not assumed to be solved by a new tray.

Self-fit decision

A careful fitter may manage a tray on a sound floor where the waste matches and access is clear. Seek help where pipes must be rerouted, the floor needs alteration, the tray is too heavy for safe handling or waterproofing is unclear. Never cut a tray unless its maker says it is designed to be cut.

Test before finishing

Protect the surface and waste from debris. Test the trap connection while access remains. Fill and flush water across the tray, check that it drains to the outlet and inspect below. After sealant has cured, test the finished shower and watch the room beneath if there is one.

Send photos

Describe the job in the contact form, then email photos of the room, the existing tray edges and floor access, with the new product's technical drawing, quoting your reference. Add whether tiles will be replaced and who will do that part.

Questions people ask

Can a new tray reuse the old waste position?

Only if the outlet lines up or the pipe can be moved with enough fall. Compare the technical drawing with the floor before buying.

How soon can the shower be used?

Wait for the bedding and sealant to cure for the times printed by their manufacturers.

How it works

From enquiry to agreement

Send my job list
  1. 01

    Describe it

    What is wrong or what you want changed, where it is and when it started.

  2. 02

    Add your details

    Postcode, how to reach you and the days that suit.

  3. 03

    Email photos

    A close view, a wider view and any model label, with your reference.

  4. 04

    Agree it in writing

    The scope, who supplies parts and how the price is worked out.

Water escaping now

Do these three things first

Safety comes before the enquiry. Send the form afterwards for the repair and any making good.

  1. 01

    Turn it off

    Close the internal stop valve if it is safe to reach. It is often under the kitchen sink or where the supply enters.

  2. 02

    Stay clear of electrics

    Do not touch wet sockets, fittings or appliances. Switch off at the consumer unit only if the way to it is dry.

  3. 03

    Get someone to attend

    Phone someone who can come now. A web form is not the place for water that is still running.

One list, however many jobs

Add what needs fitting or replacing, tell us the postcode, then email photos.