Single, twin, positive and negative head pumps

Published

Shower pump types explained: single and twin impellers, positive and negative head, supply requirements, notification rules and what to check before choosing.

Shower pumps are described in two separate ways. Single or twin says how many water streams the pump handles. Positive, negative or universal says whether gravity can start water moving through the pump without help. You need both answers, plus the type of hot water system, before a model can be chosen.

Start with the water system

A conventional domestic shower pump boosts stored water: a cold water cistern, usually in the loft, and a hot water cylinder fed from it. The Stuart Turner Showermate Universal instructions limit that range to vented stored water systems and say it must not be connected directly to the mains.

If your home has a combination boiler or a mains pressure cylinder, this kind of pump is not the answer. Poor flow there needs diagnosing, and any boiler question belongs with a Gas Safe registered engineer where the boiler burns gas.

Single and twin pumps

Type What it does Typical layout
Single Boosts one stream Water after a mixer valve, or one supply only
Twin Boosts two streams separately Hot and cold feeding a mixer shower

With a twin pump, both inlets are pumped before the mixer, which keeps the two sides matched. A single pump may sit between a mixer and an overhead outlet, or serve a feed that needs help on its own. The valve maker's pressure limits still apply after pumping.

Positive and negative head

Head is the vertical relationship between the stored water and the point being fed.

  • Positive head: gravity alone pushes water through the pump and out of the open shower, enough to trigger the pump's flow switch. This usually means the cistern sits comfortably above the shower head.
  • Negative head: the outlet is level with or above the cistern, or the natural flow is too weak to start the pump. A pump rated for negative head uses pressure sensing and a small pressure vessel to notice an open outlet.
  • Universal: a label for products that handle either condition.

Salamander's guidance for its own range puts figures on this: a positive head system delivers at least 2 litres a minute by gravity at the outlet and a negative head system less. Where flow cannot be measured, it suggests checking for more than 600 mm between the base of the cold tank and the highest point in the pipework after the pump. A positive head pump suits only the first case; a universal pump suits either.

To measure flow, turn off any existing pump, open the hot side alone and catch the water for one minute, then repeat for cold.

A negative head pump keeps the pipe beyond it pressurised and starts when opening an outlet makes that pressure fall. A small pressure vessel is usually fitted to guard against false starts. A dripping tap or slow leak downstream can still start it with everything apparently shut, so have that investigated.

Do not judge by floor numbers alone. A loft shower room, or a rain head fixed to the ceiling, can turn a house that has good pressure downstairs into a negative head job. Open the existing shower fully and see whether it runs by gravity, then measure from the underside of the cistern to the shower head.

Supply pipes and water temperature

Pumps move more water than gravity fittings, so the cistern, cylinder and pipes must keep up. The same instructions call for:

  1. enough hot and cold storage for everything that may run at once;
  2. dedicated feeds to the pump, with air kept out;
  3. at least 22 mm pipework between the cold storage and the hot storage;
  4. inlet water no hotter than 65°C;
  5. a dry, frost protected position that can be reached for service.

They also advise against putting the pump in a loft. These figures belong to that product range. Another maker may differ, so read the sheet for the model you are considering.

Pressure rating is not the whole choice

Pumps are sold by pressure, often in bar. A higher number is not automatically better. It must stay within what the valve, hoses and head accept, and the stored water must last long enough for the way the shower is used. A large rain head and body jets empty a small cylinder quickly.

Notification and electrics

The notification list in the Water Fittings Regulations includes a pump or booster drawing more than 12 litres per minute where it is connected directly or indirectly to a supply pipe. Ask your water company how that applies before installing.

A pump also needs an electrical connection designed for it. In England, a new circuit, or any addition or alteration to a circuit in the zone around a bath or shower, is covered by building control rules, so use a qualified electrician.

Information that narrows the choice

Collect photographs of the cistern with its pipe outlets, the cylinder and its label, the shower valve, the outlet, and the intended pump space. Note cistern size if marked, the height difference, and how many outlets would be fed. If an old pump is being replaced, its rating plate is the most useful picture of all, and say if the pump is built into the shower unit.

Describe these in the contact form, say plainly that the job is a pump or a supply question, and email the photos afterwards. Whether anyone can take it on, and what it involves, is confirmed after the details are reviewed.

Questions people ask

Can a shower pump go on a mains fed supply?

A pump designed for stored water must not be connected to the mains. The Stuart Turner Showermate instructions say so directly.

What does universal mean on a shower pump?

It is used for pumps that can work in both positive and negative head conditions, within the limits in the instructions.

One list, however many jobs