Double basin plumbing for twin basins: plan trap arrangement, waste fall and pipe size, hot and cold supply, valves, spacing, wall support and testing.
Twin basins need either a trap each or an approved kit joining both outlets to one trap, a branch pipe that can carry both with fall, and hot and cold supplies that still give good flow when both taps run. Plan these behind the furniture before it is ordered.
Spacing and furniture
Allow elbow room between the bowls: a vanity that fits two basins on paper may be uncomfortable in use. Check door swing and drawer cut-outs against each trap. A double drawer unit often leaves two small zones for pipework.
Waste choices
| Arrangement | Suits | Check |
|---|---|---|
| Two separate traps, one branch | Wider spacing | Branch size and junction |
| One trap, twin outlet kit | Close bowls | Maximum spacing and kit instructions |
| Two separate branches | Different walls or stack points | Two connections and access |
Long horizontal pipes between an outlet and a shared trap leave a dirty, smelly section. Approved Document H gives a 32 mm trap with 75 mm seal for a washbasin, and branch tables where more appliances or longer lengths need a larger pipe, commonly up to 50 mm. Use the table for your layout and make junctions swept in the direction of flow. Include a cleaning access.
Water supply
Work out where hot comes from and its pipe size. Feeding two basins from one small branch can starve them. Run an adequately sized pipe to a tee near the unit, then branch to each tap with a servicing valve on every connection. Keep cold from warming beside hot. On gravity systems, choose low pressure taps and check whether one outlet robs the other.
Hot water at the far basin may take longer to arrive; short, insulated runs help.
Mixed supplies
If cold is on the main and hot from a tank, each mixer needs the protection its instructions require. See mixer check valves.
Wall and floor
Two basins, a stone top and a large unit are heavy. Fix a wall-hung vanity into solid masonry or timber added to a stud wall. Level it carefully; a long top exaggerates any slope.
Setting out
- Mark each bowl centre and the finished heights.
- Draw trap and waste kit from product dimensions.
- Mark the supply pipes left hot, right cold at each tap.
- Check socket and mirror positions with the electrician.
- First fix, pressure test and photograph.
Testing
Run both hot taps together, then both cold, then fill both basins and release them at once. Listen for gurgling, which suggests the traps are being siphoned or the branch is struggling. Look underneath with dry paper during and after.
Adding to an existing bathroom
A second basin changes the waste run and sometimes needs wall opening or floor lifting. The existing branch may be too long or the wrong size once extended. Measure back to the stack before buying furniture.
Asking for a quote
Give room dimensions, hot water system and unit drawings on the contact form and email photos of current pipes with your reference. State whether furniture is already bought.
Wastes and overflows
Record whether each basin has an overflow, since that decides whether its waste needs a slot. Keep both traps, or the shared one, where a bowl can be placed underneath for cleaning. A drawer that has to be removed to reach a trap is acceptable only if it comes out easily.
Is a second basin worth it?
A wider single basin with two taps may give a similar benefit with one waste, simpler furniture and less pipework. Consider how often two people use the room at once, and what storage is lost to a second trap. Ask for both layouts to be drawn before deciding.
Label each valve with the basin it serves.
Questions people ask
Can two basins share one trap?
Some kits join two outlets to one trap with limited spacing. Follow the kit and the drainage guidance.
Will the hot water cope?
Two taps together can lower flow, especially on gravity systems. Check before adding the second basin.