Non return valve on mixer tap requirements: single flow designs, unequal supplies and hoses, where to fit check valves, flow direction and later maintenance.
A mixer tap needs check valves when its design or your water supply allows one stream to flow back into the other, or when its outlet can create a backflow risk. Single flow mixers and hose outlets are the usual cases. The tap instructions state what to fit.
What the valve does
A single check valve lets water pass one way and closes against reverse flow. Water Regs UK says it is rated for contamination risks no greater than fluid category 2, such as hot water crossing into cold. Higher risks need a stronger arrangement such as a double check valve or an air gap.
When it applies
| Situation | Typical requirement |
|---|---|
| Single flow mixer on basin, bath or sink | Single checks on both supplies, plus outlet gap |
| Unbalanced supplies | Check valves as maker states |
| Pull-out spray that can enter a bowl | Valves supplied or specified by maker |
| Bi-flow spout with correct gap | May need none for crossflow |
| Hose that can reach a toilet | Much higher protection needed |
The first row follows Water Regs UK guidance for basin and bath taps. It also reminds readers that the local water undertaker has the final say on the level of protection. A Bristan monobloc sheet supplies non-return valves for hot and cold with a pull-down spray tap, and still says that this model must be fed from a storage cistern on both sides. Check valves in the box do not make a hose tap suitable for any supply.
Where to put them
Fit them on the supply pipes, close to the tap and in an accessible place, between the isolating valve and the tap unless the maker says otherwise. Some taps accept small inserts inside the flexible tail connection. Check the arrow on the body: a reversed valve stops flow completely.
Fitting points
- Isolate both supplies and drain the branch.
- Clean pipe ends.
- Check the arrow towards the tap.
- Make joints without straining the valve body.
- Do not solder near seals unless the product allows it and the cartridge is removed.
- Restore water and check each side.
A joint must not be concealed, and a mechanical backflow device in a concealed position has material requirements, so keep them visible in a cupboard.
Flow effect
Springs create resistance. On a mains supply this is usually unnoticed; on a gravity hot supply with little head it can reduce flow. Choose a low resistance type where permitted, or a mixer with a bi-flow spout. Never remove a required valve to gain flow.
Maintenance
Water Regs UK recommends checking single check valves every twelve months and replacing non-verifiable ones every ten years. Debris, scale or a worn spring can let them stick. Signs include warm water from the cold tap, loss of flow or banging.
Combined fittings
Isolating valves with built-in checks save space. Confirm the combination is approved and note which way it faces. A label inside the cupboard saying where the devices are helps the next person.
Related changes
If you are moving from two taps to one, review two taps to one mixer first. For hoses, see pull-out taps.
For help deciding what your setup needs, send the tap model and photographs of the pipes through the contact form, with images emailed against your reference.
Records for the next job
Photograph the finished cupboard with the flow arrows visible, note the date of fitting and keep the product packaging or code. When a tap is changed again, check whether the new one has its own internal checks so that two sets are not stacked without reason, and never assume that an old valve left in the pipe still seals.
Questions people ask
Are a check valve and non return valve the same?
In household talk usually yes, but the water rules refer to rated check devices, so use an approved one.
Do all mixers need them?
No. It depends on the design, the supplies and the backflow risk.