Replacing a shower pump: record the old unit, match the new one, check feeds and electrics, flush the pipes, prime it and test before closing the cupboard.
Replacing a shower pump means fitting a unit that suits the same stored water system, reconnecting it without stressing its ports, and having the electrical connection made and checked properly. A pump with matching connections is not automatically a match. Choosing between single, twin, positive and negative head is covered in shower pump types.
Before ordering
Photograph the old pump from above and both sides. Record:
- make, model, pressure rating and fuse size;
- which pipe is hot or cold, inlet or outlet;
- connection sizes and hose positions;
- the space and floor the pump sits on;
- where the isolating valves are and whether they close fully;
- what actually happens: silence, humming, running on, pulsing or leaking.
Rule out simpler causes
A quiet or struggling pump may not have failed. With safety in mind, check these first:
| Symptom | Check before replacing |
|---|---|
| Nothing happens | Switched spur, fuse and any tripped protective device; have an electrician investigate repeat trips |
| Weak or uneven flow | Isolating valves fully open, inlet strainers clean, tank holding water |
| Spluttering | Air in the supply, often from a shared or badly placed feed |
| Louder than before | Pipes or panels touching, a pump screwed down hard, a shifted mat |
Do not run it repeatedly while testing if no water is reaching it.
Check the installation, not only the pump
An old arrangement can be the reason the last pump died. The Showermate Universal manual is one maker's example. For that range it requires:
| Item | Requirement in that manual |
|---|---|
| Cold feed | Dedicated from the storage tank, 25 mm minimum below the cylinder's cold feed |
| Hot feed | Dedicated from the cylinder, arranged to keep air out |
| Mains water | Never connected |
| Inlet temperature | 4 °C to 65 °C |
| Inlet pipe | No non-return valve |
| Servicing | Separate full flow isolating valves, strainers, easy access |
| Position | Dry and frost free, loft not recommended, 80 mm air gap around the pump |
It also sets limits on the height of water above and below the pump. The maker's support answers give 4 metres from the cylinder as a condition for fitting under a bath. Read the manual for the model being installed.
Fit the replacement
- Switch off and isolate the electrical supply, and prove it is dead.
- Close the water valves and catch what drains from the hoses.
- Disconnect and lift out the old unit.
- Flush the pipework so grit, flux and debris cannot reach the new pump.
- Set the new pump level on its mat or feet, without screwing it down if the maker says not to.
- Connect hoses as straight as possible; that manual limits bends to 30 degrees. Move the pipes if the ports do not line up.
- Open the valves and prime the pump with the power off. Running it dry can ruin the seal.
- Restore power only after the wiring has been checked.
Electrical connection
The same manual calls for a qualified installer, a double pole switched fused spur with the fuse it specifies, earthing, and recommends 30 mA residual current protection. In England, adding or altering a circuit in the zone around a bath or shower falls within building regulations notification.
Water company notice
A pump drawing more than 12 litres a minute and connected to a supply pipe directly or indirectly appears on the notifiable work list. Ask the water company whether yours is caught.
Commissioning checks
Open and close every outlet the pump serves until the air has gone. The pump should start and stop cleanly, with no running while everything is shut. Inspect each joint, listen for rattling panels and recheck after a few showers. Keep the manual and purchase record near the pump.
To arrange the water side, give the old model on the contact form and email the photographs and a picture of the cylinder and tank.
Questions people ask
Can I reuse the old flexible hoses?
Follow the new pump's instructions. Stuart Turner says to use only the hose set supplied with its pump.
Is a noisy pump always worn out?
No. Loose pipes, a resonant shelf, trapped air or a poor mounting can all make noise, so check those before replacing it.