
Toilet soil pipe connection guide: measure the outlet and pipe, choose a straight, offset or angled pan connector, keep the fall and test the seal.
A toilet joins the soil pipe through a pan connector: a sleeve that seals over the pan spigot at one end and into the pipe socket at the other. Choose it from measurements of both, and never rely on a connector to correct a badly placed toilet.
Measure the two ends
- Pan outlet: horizontal or downward, outside diameter, and height of its centre above the finished floor.
- Soil socket: inside diameter, material (plastic, cast iron or clay) and centre position.
- Gap: distance between them along the pipe line.
- Offset: sideways and vertical difference between the two centres.
- Direction: straight back, to one side, or down through the floor.
Take the pan figures from its drawing before the old toilet comes out, and verify afterwards.
Pick a connector
| Situation | Typical connector |
|---|---|
| Centres aligned, short gap | Straight rigid |
| Small mismatch | Offset rigid, sold in set offsets |
| Pipe through the floor, horizontal pan | 90 degree bend |
| Awkward angle within a short range | Flexible, within its stated limits |
| Longer distance | Pipe and fittings designed with the correct fall |
Makers state the sizes each connector fits. For example, McAlpine's 90 degree flexible WC connector lists a 97 to 107 mm inlet and an outlet that fits inside 110 mm PVC-U or cast iron soil pipe. Check yours against the old pipe, particularly in clay or cast iron.
Requirements to keep
Approved Document H shows branch pipes of at least 100 mm for a WC with an outlet over 80 mm, with a minimum fall of 18 mm per metre for a single connection. On unventilated length it prints 15 m in Table 2 but 6 m for a single WC in Diagram 3, and the stricter 6 m is the one to use. A WC with a smaller outlet takes at least 75 mm. A ground floor toilet should discharge straight to a drain only where the floor to drain depth is 1.3 m or less. Longer or more complex runs may need ventilation.
Foul water must go to the foul system. The Building Regulations require adequate drainage for it, so never connect a toilet to a rainwater pipe or gully serving surface water.
Make the joint
- Clean both mating surfaces and cut away old putty without damaging the pipe.
- Check the socket is not cracked or chipped.
- Dry fit: pan in position, connector measured, nothing stretched.
- Wet the seals with the lubricant the maker permits, if any.
- Seat the connector in the socket, then bring the pan to it, keeping it square.
- Confirm the seals have not folded back.
- Fix the pan to the floor without twisting it.
Avoid sealant as a substitute for a correctly sized seal. It prevents later removal and hides poor fit.
Test
Flush with the cistern full several times while watching the joint from below or behind, using a torch and dry tissue. Add paper to a test flush. A slow leak may only appear after repeated use, so look again the next day before boxing in. Leave an access panel where the connector will be hidden.
Warning signs
- Smell with no visible water: a seal is not seated or the trap is losing its water.
- Pan emptying slowly: fall, obstruction or a connector projecting into the flow.
- Water at the back of the floor after flushing: stop using it.
- Movement in the pan: fix the pan, or the seal will fail.
Scope
Changing a connector beside an existing pipe is a contained job. Altering a stack, breaking into drains or moving the toilet is more, and flats may need the freeholder's permission. Start with the contact form and email photos of the outlet and pipe with a tape in view. For taking the old pan off, see toilet removal.
Questions people ask
Can I use a flexible connector anywhere?
Use the shortest suitable one within its stated range. Long sagging runs collect waste and a connector cannot create a fall.
Can I move the toilet to another wall?
Only with a drainage route that keeps size, fall and access requirements. Plan it as drainage work and check building control rules.
